Recording configuration
124
Siemens Building Technologies
Fire Safety & Security Products 03.2009
Setting Function Note
Frame rate The frame rate at which the post-alarm
recordings are to be saved.
Only available
z in the recording modes alarm input, priority
alarm and software trigger
z if the Single shot checkbox is not marked.
z Software trigger We recommend setting the
frame rate of cash box cameras to 4.0/s.
Single shot Instead of a video sequence, only up to
5 single images will be recorded. These
individual images will be recorded at the
maximum frame rate of the camera.
Only available in the recording modes alarm
input, priority alarm, and software trigger.
Logbook entry When an event occurs, an entry will be
written in the logbook.
Only available in the recording modes alarm
input, priority alarm and software trigger and
suspicion
Camera to monitor
output
If an event occurs, the live image of the
selected camera will be activated on a
monitor.
Only available
z for analog cameras
z in the recording modes motion, alarm input,
priority alarm and software trigger
z if the checkbox External video monitor on the
Cameras tab is marked for the camera
affected.
Write protection If enabled, the recordings of the affected
camera cannot be overwritten.
Only available in the recording modes alarm
input, priority alarm and software trigger.
Alarm call In case of an event, a connection will be
made to a SISTORE RemoteView client
and the live image of the selected
camera is shown there.
Only available
z in the recording modes motion, alarm input and
priority alarm
z if the connection is configured on the Alarm
connection tab (
436Hsee "1357HConfiguring the alarm
connection", page
1358H143).
The login to the SISTORE RemoteView client
takes place automatically.
Alarm list entry When an alarm occurs, a list of the
incoming alarm messages can be
displayed at the left edge of the screen.
Only available in the recording modes alarm input
and software trigger.
Can be cancelled by
user
When the function alarm message is
activated, the user can cancel an alarm
after having acknowledged the alarm
message.
Only available in the recording mode alarm input.
FTP In case of an alarm, the alarm message
will be stored as an MSG file and an
alarm image as a JPEG in the root
directory on the FTP server.
Only available
z in the recording modes motion, alarm input,
priority alarm and suspicion
z if an FTP server is configured on the FTP tab.
E-mail/SMS When an event occurs, the text entered
will be sent by e-mail or SMS.
Only available
z in the recording modes alarm input and priority
alarm
z if e-mail and/or SMS delivery is configured on
the E-mail and SMS tab (
437Hsee "1359HConfiguring e-
mail notification", page
1360H136 438Hor "1361HConfiguring
SMS notification", page
1362H140).
The following variables can be used in the text:
z %C = camera name
z %X = date and time of the start of the event
Acoustic message The acoustic signal selected is played
when an event occurs.
Only available in the recording modes motion,
alarm input and priority alarm.
Comentários a estes Manuais