Technical data
MOTION DETECTORS IR160W6-10 IR60W6-10
Coverage area Wide angle: 18 m
Curtain (IRS272): 25 m
Wide angle: 12 m
Settings Sensitivity: standard / low (selectable by jumper) Sensitivity: standard / low (selectable by switch)
Frequency
Radio protocol
868.35 MHz
SiWay
868.35 MHz
SiWay
Event Transmission Alarm, Tamper, Test, Supervision,
Low Battery
Alarm, Tamper, Test, Supervision,
Low Battery
Test mode / activation Walk test & Alarm transmission test by tamper or external
magnet activation
Walk test & Alarm transmission test by tamper or external
magnet activation
Walk test auto reset 1 minute after activation 1 minute after activation
Inhibition time Approx. 2 minutes Approx. 2 minutes
Power management Automatic power saver Automatic power saver
Power consumption Standby: 8 – 12 uA
Max. 16 mA
Standby: 8 – 12 uA
Max. 15 mA
Battery Lithium 3 V, Type: xx123, Size: 2/3 AA Lithium 3 V, Type: xx123, Size: 2/3 AA
EMI rejection up to 2 GHz > 10 V/m > 10 V/m
Environment conditions
- Operating temperature
- Storage temperature
- Air humidity (EN60721)
- Housing protection
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
Housing Material ABS – V0 ABS – V0
Security grade
Environmental class
(EN 50131-5-3, EN 50131-2-2)
Grade 2
Class II
–
–
Detection pattern
Wide angle mirror (standard)
Curtain mirror (IRS272)
Wide angle lens (standard)
Dimensions