DETECTORS AND
ACTUATORS
IOPW6-11 + IMSW6-10 IRCW6-11 IKPW6-10 ISRW6-12
Characteristics Coverage area: 60 m²
(max. mounting high: 3 m)
LED flashes once every approx. 50 s
Acoustic output power: > 85 dB at 3 m
distance
Wireless range: 100 m in
open space
Wireless range: up to 300 m in
open space
Siren output level:
100 dB at 1 m
Frequency
Radio protocol
868.35 MHz
SiWay
868.35 MHz
SiWay
868.35 MHz
SiWay
868.35 MHz
Si2Way
Event transmission Alarm, Tamper, Supervision, Low Battery Set, Unset, Part set,
Optional control, Panic
Set, Unset, Part set, Optional
control, Panic, Low battery
Tamper, Supervision, Low
battery
Test mode / activation Alarm transmission test (PCB button) or
self test by front test button
LED light up upon key
activation
Beeps upon Set / Unset
activation
Optional system Set / Unset
acoustic or visual confirmation
(user-selectable)
Power consumption Standby: typically 40 µA
Max. 410 mA
Standby: < 1uA
Max. < 28 mA
Standby: approx. 11 uA
Transmission: approx. 16 mA
External power: nom. 12 V DC
(9 – 14 V DC)
Note: if external power is
connected, the battery shall be
installed anyway
Battery 3 x Alkaline 1.5 V, type: LR6, Size: AA Lithium 3 V – type: CR2032 Lithium: 3.6 V – type: XL-050F,
Size: 1/2 AA
ER34615M
3.6 V, 14 Ah, D size
EMI rejection up to 2 GHz > 10 V/m > 10 V/m > 10 V/m > 10 V/m
Environment conditions
- Operating temperature
- Storage temperature
- Air humidity (EN60721)
- Housing protection
-10 to +50 °C
-25 to +70 °C
< 93 % r.h., non condensing
IP30
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non
condensing
IP41
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
-20 to +70 °C
-20 to +80 °C
< 95 % r.h., non condensing
IP54
Housing material ABS ABS-HB ABS-V0 Polycarbonate
Compliance EN 14604:2005 – – –