Siemens LFL Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para não Siemens LFL Series. Burner Controls - System Control Engineering, Penrose Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Brahma CE11 U MICROFLAT
Restart attempt •
Plug in electrical connections •
Single gas valve •
Volatile lock-out •
Pre-purge 1.5 seconds •
Flame failure safety time 10 •
seconds
Ionizationameelectrodecontrol•
240 or 110 volt AC•
#B1150
Brahma CM11 U MICROFLAT
Restart attempt •
Plug in electrical connections •
Single gas valve •
Non Volatile lock-out •
Pre-purge 1.5 seconds •
Flame failure safety time •
10 seconds
Ionizationameelectrodecontrol•
240 or 110 volt AC•
#B1152
Brahma CE12 U MICROFLAT
Restart attempt •
Plug in electrical connections •
Pilot / Main Gas (2 valves) •
Volatile lock-out •
Pre-purge 1.5 seconds •
Flame failure safety time 10 •
seconds
Ionizationameelectrodecontrol•
240 or 110 volt AC•
#B1154X
Burner Controls with integral ignition
System Control Engineering NZ Ltd For Gas Combustion & Control Equipment
Tel : 09-636-1401 • Fax: 09-636-1525 • [email protected] • www.systemcontrol.co.nz
Brahma CM12 U MICROFLAT
Restart attempt •
Plug in electrical connections •
Pilot / Main Gas (2 valve) •
Non Volatile lock-out •
Pre-purge 1.5 seconds •
Flame failure safety time •
10 seconds
Ionizationameelectrodecontrol•
240 or 110 volt AC•
#B1154
Brahma CE31 U MICROFLAT
Restart attempt •
Plug in electrical connections •
Single gas valve •
Volatile lock-out •
Pre-purge 1.5 seconds •
Flame failure safety time •
10 seconds
Ionizationameelectrodecontrol•
240 or 110 volt AC •
Air pressure Proving / Fan•
#B1156
Typical Photo
Non Volatile Lock out versions require an external re set button to reset.
6.1
Section 6
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Section 6

Brahma CE11 U MICROFLATRestart attempt •Plug in electrical connections •Single gas valve •Volatile lock-out •Pre-purge 1.5 seconds •Flame failur

Página 2

Brahma RE3 CONTROLPlug in base •UV Cell or Flame Rod sensing •Green light - Power on •Red light - Flame on •Two electrical change-over contacts •

Página 3

Satronic FFW 930.1 CONTROLPlug in base •UV Cell or Flame Rod sensing •Flame on indication•Two electrical change-over contacts •240 volt AC•#SA069

Página 4

System Control Engineering NZ Ltd For Gas Combustion & Control EquipmentTel : 09-636-1401 • Fax: 09-636-1525 • [email protected]

Página 5

Brahma CM32 EUROFLATRestart attempt •Plug in electrical connections •Pilot and Main gas valves •Non Volatile lock-out •Pre-purge - 5 or 30 seconds

Página 6

FENWALL BURNER CONTROL C/W WIRING LOOM12 VDC•Integral Ignition transformer•Inter purge time 25 seconds•Trial for ignition time ( TFI ) 10 • sec

Página 7

Satronic TF830.3 - OIL BURNER CONTROLLEROil burner control•Plug in base (SA7531001)•Single stage operation•MZ 770S / UVD 970 Flame detector •Pre -

Página 8

Satronic TF834.3 - OIL BURNER CONTROLLEROil burner control•Plug in base (SA7531001)•2 stage operation•MZ 770S / UVD 970 •Flame detector Pre - pur

Página 9

Satronic MMI 810.1 MOD 43Forced draught gas burner control•Plug in base (SA7531001)•Pilot / Main gas valve •Remote reset / Flame failure •indic

Página 10

Satronic MMG 870.1 MOD 65Forced draught gas burner control•Plug in base (SA7531001)•Pilot / main gas valve •Remote reset / Flame failure •indicato

Página 11

Siemens LGB 21 350 A27 CONTROLForced draught / atmospheric gas / •oil burner controlPlug in base (C16800)•Pilot / Main gas valves •Single or two st

Página 12 - Flame deteCtors

Siemens LOA 24.171B27Atmospheric Gas burner control•Plug in base (Z3061)•Remote reset / Flame failure •indicator 2 Stage operation•Post ignition t

Comentários a estes Manuais

Sem comentários