TC65Smart
User Manual
Rev. 2-1.0 25
3.4. Indication Mechanisms.
The Terminal is equipped with 4 LED indicators for visual control of operation.
Fog. 12
Indicator
PWR/STATE
Indicator
“DBG”
Indicator
SIM1
Indicator
“SIM2”
The operation of the indicators “SIM1” and “SIM2” has already been described in
Clause 3.2.
The indicator “DBG” is connected in the Terminal to the output GPIO5 of the module
TC65. It flashes upon recording of log. “1” in GPIO5 by means of АТ commands for
GPIO control (or through JAVA) and can be applied by the user for choice.
The indicator “PWR/STATE” is designed for the terminal status indication.
o If it is not flashing – electric power supply is not fed;
o If it is flashing continuously – the module is started and operates normally;
o Frequent flashing – it determines that the Controller is enabling or disabling
the module;
o Rare flashing with predominant off-status - power is supplied, the module is
disabled;
o Rare flashing with predominant on-status – the terminal is conducting the
DTR signal expectation for either enabling or disabling.