Siemens CCBS1337-MP Manual de Instruções Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
Installing the
Camera
13
Siemens Building Technologies
Fire Safety & Security Products 03. 2005
7 Installing the Camera
7.1 Installation
1.
Connect the BNC cable to the video output
2.
Connect the power source to the power terminal
Caution:
If using a DC supply, make sure the polarity is correct. Incorrect connection may cause malfunction
and/or damage to the camera.
3. To reduce radiation sufficiently, please wind one turn around the core, see figure
below
Location Core illustration for what camera
Power cable
LP
Y/C cable
LP / MP
EIM-0050751G
4. Adjust the back focus
The back focus is factory-adjusted before delivery for a CS mount lens. If re-
adjustment is necessary, please loosen screw
, set the camera to AES mode
(see section 7.2.14.2: BACK FOCUS), then rotate the back focus wheel until a
sharp image appears. Tighten screw .
7.2 Function Settings
Select ENTER on the OSD; the menu will appear on the display and will disappear
after 30 seconds if no action occurs. The shaded setting area means an item is
selected; it keeps blinking.
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 25 26

Comentários a estes Manuais

Sem comentários