Página 1 - User manual

IP-Module IP-Module CFVA-IP IP-Module CVVA-IP User manual Issue 07/2005 Fire Safety & Security Products Siemens Building Technologies

Página 2

Technical data 5.2 Technical data for IP-Module CVVA-IP Electrical supply 12 V DC/24 V AC Power requirement max. 6.0 W Operating temperature ran

Página 3 - Contents

Installing the IP-Module6 Installing the IP-Module 6.1 Installing IP-Module type CFVA-IP Fig. 1 Exploded view of IP-Module CFVA-IP IP-Module fixing

Página 4

Installing the IP-Module 7. Place the camera body on the IP-Module and screw both units together using the two screws supplied. 8. Connect the LAN cab

Página 5 - 1 Introduction

Installing the IP-Module IP-Module fixing The IP-Module features two apertures through which you can feed the cables:  An aperture in the base  An a

Página 6

Establishing initial communication with the device 7 Establishing initial communication with the device The factory settings for the IP address and

Página 7 - 3 Ordering data

Establishing initial communication with the device The client PC IP address is now displayed. In this example, we have assumed IP address 10.11.12.13

Página 8 - 4 Norms and Directives

Checking device accessibility 8 Checking device accessibility Your device is accessed in the network via its IP address. The IP address is either pr

Página 9 - 5 Technical data

Device homepage9 Device homepage 9.1 Calling up the device homepage There are two ways of calling up the device homepage:  Using Internet Explorer

Página 10 - Technical data

Device homepage 2. Click on the Start button.  The Web-Cam IP Manager program window will now display a list of all the devices available for commun

Página 11 - 6 Installing the IP-Module

Device homepage9.2 Components of the device homepage Fig. 3 Device homepage 1 Buttons for displaying live video images. See section 15.1: Disp

Página 12

Equipment availability and technical specifications subject to change without notice. Data and design subject to change without notice. Supply subject

Página 13 -  An aperture in the side

Configuring network settings 10 Configuring network settings 1. Call up the device homepage. See section 9.1: Calling up the device homepage. 2. Sel

Página 14 - 7.2 Mapping a network route

Configuring network settingsGateway (Next Hop) Enter the gateway IP address in this box. The gateway is the computer in the network, which establishe

Página 15

Configuring network settings Like the IP address, the subnet mask also consists of four numbers in the range 0 – 255, all separated from each other by

Página 16

Configuring network settings Each device's IP address or MAC address is unique. 3. Select the device whose IP address you want to change. 4. Clic

Página 17 - 9 Device homepage

Configuring image parameters 11 Configuring image parameters 11.1 Configuring general image parameters 1. Call up the device homepage. See section 9

Página 18

Configuring image parametersOverlay text You can select the parameters that are to be overlaid on the live video image here. The following options ar

Página 19 - Fig. 3 Device homepage

Configuring image parameters 3. Enter the desired settings in this dialogue window. 4. Select the quality level for each resolution from the options

Página 20 - Fig. 4 Network settings

Setting the date and time12 Setting the date and time 1. Call up the device homepage. See section 9.1: Calling up the device homepage. 2. Select Dat

Página 21

Configuring user names and passwords 13 Configuring user names and passwords You can define user names and passwords for device configuration and im

Página 22

Restarting the IP Module14 Restarting the IP Module Certain settings changes (e.g. network settings) will only come into effect after a device resta

Página 23

3Siemens Building Technologies Contents 1 Introduction ...

Página 24

Restarting the IP Module Restart by Ping Watchdog The watchdog is not active when the camera transmits a video stream. 1. Activate the Enable re

Página 25 -  Standard

Live video15 Live video 15.1 Displaying live video The data stream consists of individual JPEG-coded images, separated from each other by markers (b

Página 26 -  NTSC/EIA

Live video 1 Resolution submenu 2 Text overlay. See section 11.2: Configuring text overlay. 3 Display area for live video 4 Status.  Playing  Pa

Página 27 - Fig. 5 Date and time

Establishing access to the device via internet16 Establishing access to the device via internet If it is necessary to be able to access your device

Página 28 - Fig. 6 Security

Establishing access to the device via internet connection is interrupted, the newly allocated IP address must be assigned to your domain name, e.g. &l

Página 29 - 14 Restarting the IP Module

Embedding live video images in a dedicated HTML page17 Embedding live video images in a dedicated HTML page Embedding live video images Live vid

Página 30

Service mode 18 Service mode The service mode allows the device IP address to be reset even if the IP address that is currently allocated to the devic

Página 31 - 15 Live video

Index19 Index A Accessibility Checking device accessibility, 16 B Brightness Configuring brightness, 24 C Contrast Configuring contrast, 24 D Declarat

Página 32 - 15.3 Storing still pictures

Herausgegeben von Siemens Building Technologies © Copyright bySiemens Building Technologies AGFire & Security Products GmbH & Co. oHG D-761

Página 34

Introduction1 Introduction Thank you for deciding to buy this IP-Module. We wish you every success in using this product. If you have any questions a

Página 35 - Tab. 1 Changing parameters

General Safety Precautions 2 General Safety Precautions  Read these instructions carefully before connecting the camera and the IP-Module in order

Página 36 - 18 Service mode

Ordering data3 Ordering data 3.1 Ordering data for IP-Module CFVA-IP Type Item no. Description Weight CFVA-IP 2GF1086-8AL IP-Module for 12 V DC /

Página 37 - 19 Index

Norms and Directives 4 Norms and Directives EU Directive The following applies for the device described in this manual: The product satisfies the r

Página 38

Technical data5 Technical data 5.1 Technical data for IP-Module CFVA-IP Electrical supply 12 V DC/24 V AC Power requirement max. 6.0 W Operating