Siemens Liquid-cooled Generators Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Geradores de energia Siemens Liquid-cooled Generators. Generator Ready Load Center Save time and money Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 8
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Generator Ready Load Center
Save time and money, plus
increase home value!
The new Siemens generator ready load center
can save thousands of dollars in future generator
installation expenses while keeping initial expenses
to a minimum. Works with an automatic standby
generator or a portable generator.
Load center features:
J UL Listed
J Indoor Type 1 and outdoor Type 3R
J 225A max rated
J Flush or surface mounting
J Fits between standard stud centers
J Tin plated copper bus bars
J 22 kAIC rated
J 120/240V ~
J Main lug – convertible to main breaker with
addition of MBK150A, MBK200A, or MBK225A
for Siemens; MBK150M, MBK200M, or MBK225M
for Murray
J Main breaker – convertible to main lug with use of
lug kit part no. ECMLK225
J Installation of transfer mechanism can be
performed at time of generator installation
Automatic transfer switch features:
J UL Listed
J Operates automatically when connected to
generator
J Transfers load from utility to generator and back
to utility
www.sea.siemens.com/generators
NEMA 1 indoor
NEMA 3R outdoor
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - Generator Ready Load Center

Generator Ready Load CenterSave time and money, plusincrease home value!The new Siemens generator ready load center can save thousands of dollars in f

Página 2 - Features

Utilityonly circuitsCritical circuits(powered byutility and generator)Instead of having one interior like standard load centers, theSiemens generator

Página 3 - Knockout diagrams

200A Main BreakerBrandOne inch spaces* Max circuits*Indoor enclosure - NEMA Type 1 Outdoor enclosure - NEMA Type 3RCatalog number Dimensions (inches)C

Página 4

Wiring schematic for liquid cooled generator Siemens Energy & Automation, Inc. Alpharetta, Georgia U.S.A.4

Página 5

Wiring schematic for air cooled generatorSiemens Energy & Automation, Inc. Alpharetta, Georgia U.S.A.5

Página 6 - Installations

InstallationsSABCDFGESABDEFCSABDEFCABDEFCABFCBDEFC Traditional InstallationTraditional installationThe majority of standby generator installations ar

Página 7 - Drawing layouts for NEMA 1

Drawing layouts for NEMA 1 Main lug unit as shipped,automatic transferswitch installed in eld(automatic standby system)Main lug unit as shippedwithou

Página 8 - Drawing layouts for NEMA 3R

Subject to change without prior notice Order No.: RPFL-GENER-0609Printed in USA © 2009 Siemens Energy & Automation, Inc.Siemens Energy & Autom

Comentários a estes Manuais

Sem comentários