Siemens SPCK421 Manual do Utilizador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
16
Technical data
Controller and PSU
SPC5320.320-L1
Intrusion CP, G2
SPC5330.320-L1
Intrusion CP, G3
SPCP332.300/333.300
Smart PSU with
I/O-Expander
SPCP432.300/433.300
Smart PSU with
2-Door Expander
Number of on-board zones
8
8
4, for door control
EOL resistor
Dual 4K7 (default), other resistor combinations configurable
Dual 4K7 (default), other resistor combinations configurable
Max. number of hardwired
zones
128
Max. number of wireless
zones
1)
120
Number of on-board open
coll.
2 internal / external bell,
3 freely programmable (each max. 400 mA resistive switching
current, supplied via auxiliary output)
Number of on-board relays
1 strobe (30 VDC / 1 A resistive switching current)
2
2, for door control
(single-pole changeover, 30 VDC / max. 1 A)
Max. number of outputs
128
Programmable areas
16
Max. number of user codes
256
Intrusion Event Logs
10,000 log events
Access Event Logs
10,000 log events
Field bus
2)
X-BUS on RS-485 (307 kb/s)
X-BUS on RS-485 (307 kb/s)
Number of field devices
3)
48 (16 Keypads, 16 Door-expanders,
16 Input/Output expanders)
Tamper contact
SPC5330: Front spring tamper, back tamper,
SPC5320: Front spring tamper
SPCP333: Front spring tamper, back tamper
SPCP433/332/333: Front spring tamper
Interfaces
2 X-BUS (2 spurs or 1 loop)
2 RS232
1 USB (PC connection)
1 SPC Fast Programmer
2 card readers, Wiegand 26 bits
(standard), Clock&Data and
Wiegand 36 bit (proprietary)
1 Ethernet (RJ45)
1 Ethernet (RJ45)
Power supply
Type A (per EN50131-1)
Type A (per EN50131-1)
Input voltage
230 V AC, +10 to -15 %, 50 Hz
230 V AC, +10 to -15 %, 50 Hz
Operating current
Max. 160 mA at 12 VDC
Max. 95 mA (all relays activated)
Quiescent current
Max. 140 mA at 12 VDC
Max. 77 mA
Auxiliary power (nominal)
Max. 750 mA at 12 VDC
Max. 1500 mA at 12 VDC (750 mA per output)
Output voltage
11-14 VDC in normal conditions
(mains powered and fully charged battery)
11-14 VDC in normal conditions
(mains powered and fully charged battery)
Battery capacity / type
Max. 7 Ah / 12 V,
YUASA NP7-12FR (7 Ah)
Max. 17 Ah / 12 V,
YUASA NP17-12FR (17 Ah)
SPCP332/432: Max. 7 Ah /12 V, YUASA NP7-12FR (7 Ah),
SPCP333/433: Max. 17 Ah / 12 V, YUASA NP17-12FR (17 Ah),
Housing
Small metal housing
(1.2 mm mild steel)
Hinged metal housing
(1.2 mm mild steel)
SPCP332/432: Small metal housing
SPCP333/433: Hinged metal housing
1.2 mm mild steel
Dimensions
(W x H x D in mm)
264 x 357 x 81
326 x 415 x 114
264 x 357 x 81 (SPCP332/432)
326 x 415 x 114 (SPCP333/433)
Weight
4.50 kg
6.10 kg
4.70 kg (SPCP332/432)
6.30 kg (SPCP333/433)
Colour
RAL 9003 (signal white)
RAL 9003 (signal white)
Operating temperature
0 ~ +40 °C
0 ~ +40 °C
Relative humidity
Max. 90 % (non-condensing)
Max. 90 % (non-condensing)
1)
A wireless zone takes away a wired zone / optional RF receivers required.
2)
Max. 400 m between devices in chain configuration / cable types IYSTY 2 x 2 x Ø 0.6 mm (min.), UTP cat5 (solid core) or Belden 9829.
3)
More I/O expanders can be addressed instead of a keypad or door expander, but number of programmable inputs / outputs cannot exceed specified system limits.
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20

Comentários a estes Manuais

Sem comentários