Installation
4.3.2 DC Power Supply Wiring Examples
Figure 18: DC Power Supply Wiring Examples
Notes:
1. 125/250VDC rated equipment: A 300VDC appropriately rated circuit breaker must
be installed.
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
3. For dual DC power supplies, Separate circuit breakers must be installed and
separately identified.
4. Equipment must be installed according to the applicable country wiring codes.
19
RuggedCom
®
RuggedSwitch
®
RSG2200 Installation Guide rev115