Industry Automation and Drive Technologies - SCE
TIA Training Document
Page 47 of 65
Module E11
Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and
RF180C
Control bits from Bit0 to Bit7
Variable Description
cancel
True =interruption of a current command or a command string. FB45 then sets the
variable ready.
MOBY U/D or RF300: the variable ‘cancel’ is not available. A command has to be
canceled with the variable init_run.
command_start
True = start of a command or a command string
repeat_ command
True = command repetition: The command or command chain stored last in the IM is
reprocessed with the next MDS. However, command processing for the MDS is
started only after the MDS that was processed has exited the transmission window
(ANZ_MDS_present= 0) and a new MDS has entered the transmission window of the
reader (ANZ_MDS_present: 0 1).
False = no command repetition, or command repetition is stopped after the command
that was started with the repeat command is processed. Please note that the user
has to reset this bit in order to stop command repetition. The result of the command
repetition is fetched by the use setting command_start.
Repeat_command is not reset automatically by FB45 after the command is
processed.
The commands init_run and cancel reset the variable repeat_command. This also
interrupts a command repetition in the IM. repeat_command can be set again by the
application with the next command_start. Handling of command repetition is described
in the chapter "Command Repetition“.
Init_run
True = IM restart. In this case, FB45 is also reset and the IM re-parameterized. All
data and commands in the IM are lost. This bit has to be set in the restart OB (OB100)
for each MOBY channel or IM.
After a MOBY-IM fault, the error error_MOBY=0F is indicated to the user. The user
then has to perform an init_run.
Please note:
When loading a parameter data block from the programming device to the
SIMATIC, bit init_run is pre-assigned TRUE. The result is the automatic
execution of an IM restart.
The time to execute init_run is normally in the millisecond range. If there is
an error, this time may extend to 15s.
IM_failure
True = the IM failed. The user sets this bit in OB122 (refer to chapter "Programming
Module Failure“). FB45 then signals an error to the user (error_FB = 09) and
interrupts the current command. If the user does not program OB122, the PLC enters
the STOP mode if the IM fails.
FB45_active FB45 is just processing a command. This variable is set when the command is started
(command_start=True) and remains active until
FB45 has received the last acknowledgement from the IM
The init_run bit was set
The cancel bit was set
The IM signaled an error
ANZ_next This bit is set if the command executed last was a NEXT command
ANZ_reset This bit indicates that the command executed last was a RESET. The user started the
RESET command with "init_run“.
Notes
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________