Technical data
6.1 Mechanical and electrical data
SCALANCE W770/W730
36 Operating Instructions, 11/2014, C79000-G8976-C325-04
SCALANCE W774/W734 RJ-45 and SCALANCE W774 M12 EEC
Electrical data
Power supply Supply voltage from terminal
block/socket
24 VDC Safe Extra Low Voltage (SELV)
Permitted range 19.2 to 28.8 VDC
Version
W774-1 RJ-45, W734-1 RJ-45
Terminal block, 4 terminals
Version
W774-1 M12 EEC
M12 socket
Properties Electrically isolated, redundant design
PoE to 24 VDC non-redundant design
Supply voltage from PoE
48 VDC
Permitted range
36 to 57 VDC
Fusing
2 A / 24 VDC
1 A / 48 V PoE
Current consumption
at 24 VDC / typical
250 mA
With power over Ethernet / typical
125 mA
Power loss at 24 VDC
at 24 VDC / typical
6 W
With power over Ethernet / typical
6 W
Permitted ambient conditions
Ambient temperature During operation with the rack in-
stalled horizontally
-20 to +60
During operation with the rack in-
stalled vertically
-20 to +60
During storage
-40 °C to +85 °C
During transportation
-40 °C to +85 °C
Relative humidity
During operation
95% at 25 °C, no condensation
Operating altitude During operation 2,000 m above sea level at max. 60 °C
ambient temperature
Contaminant concentration
According to IEC 60721
Design, dimensions and weight
Degree of protection
IP30
Weight
520 g
Dimensions (W x H x D) 26 x 156 x 127 mm
(height without antenna connector 147 mm)
Installation options
Wall mounting
Installation on a DIN rail
Installation on an S7-300 standard rail
Installation on an S7-1500 standard rail
Vista de página 35