Siemens EF 83P Series Manual de Instruções Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 113
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
1-3
1.2.2 Machine Installation Precautions
Installation Site:
(1) Allow space for maintenance.
Install the machine so that the doors of the machine and
the NC unit can be opened without interference.
(2) Do not put things on the floor around the machine.
Keep the floor dry. If coolant or lubricating oil is spilled.
Wipe it up immediately.
(3) The machine and the NC unit must not be subject to
direct sunlight. Chips, coolant, and oil must not be
splashed on the machine or the NC unit.
The machine and the NC unit must not subject to any
excessive vibrations.
Ambient temperature: 0 to 40
Humidity: 75%RH or lesswithout condensation
(4) Make sure that the floor is strong enough to support the
machine. The floor must not be sloped or irregular in any
way.
(5) A number of cooling fans are used inside the floor.
Therefore, dust and mist must be kept to a minimum.
(6) Allow space for easy removal of the chip conveyor and
the coolant tank.
Power Supply:
(1) Only an authorized electrical technician should perform
work with the power cable connections.
(2) No electrical noise generating sources, such as electric
welders or electric discharge machines, can be near the
machine. Take care to insulate the machine from any
adverse effects that might be caused by nearby
equipment.
(3) An excessive voltage drop due to an insufficient power
capacity will cause a malfunction of the NC unit. The
power cables must be connected directly and
independently to the plant power distribution panel.
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 112 113

Comentários a estes Manuais

Sem comentários