High performance
No duration upto 55°C
Contactors are suitable for operation in service temperature
upto 55°C without derating. This avoids selection of higher
rated contactor, thereby reducing cost.
Long Life
Superior design of current carrying parts, contact system and
the magnet system increases the reliability results into higher
electrical and mechanical endurance.
High short-time rating
Contactors have a high short-time rating, which makes them
suitable for applications having high starting currents and long
run-up times.
High reliability
High insulation voltage and impulse withstand voltage capacity
ensures reliable performance during occasional abnormal
increase in supply voltage.
Double break parallel bridge contact mechanism
This mechanism is available for auxiliary contacts. Such contact
mechanism ensures reliable contact at low voltage and low
currents (5mA at 17VDC). It also offers unmatched reliability.
(Chances of 2 mal-operations in 100 mill. operations as against
4460 for single bridge contacts)
Double Break Parallel Bridge
Auxilary Contacts
Positively driven contacts
3TF contactors satisfy the conditions for positively driven
operation between the main power contacts and the NC
contacts. NC contacts positively open before the main contact
closes. This is extremely important when power contactors are
used in safety circuits of critical applications.
SIGUT Termination
Figure touch proof terminals*
It protects against accidental contact with live parts which
ensures operator safety.
Funnel shaped cable entries
Reduce wiring time by facilitating quick location of the
connecting wire.
Cable end-stop
It decides the insertion depth of the connecting wires. Since
the insertion depth is predetermined, insulation of the cable
can be cut accordingly and the possibility of insulation
getting inadvertently caught under the terminal, is avoided.
Captive Screws
This feature prevents the screws from falling down thereby
facilitates the wiring. Hence, the contactors are delivered
with untightened terminals. This eliminates the operation of
untightening terminals before wiring.
Lug less termination
This feature helps in reducing the termination time.
* Finger touch proof terminals are available upto 85 A
User friendliness and safety
Arc Chamber Interlock (45A and above)
It prevents the contactor from switching ON, if the arc chamber
is not fitted properly. Thus avoids accidents to plant and
personnel.